Urine Meter

Pre-Connected Urine Meter

Reduced risk of CAUTI, safeguarding health

Designed to minimize the exposure of the catheterized urinary tract to external contaminants and pathogens, which have been shown to significantly reduce the risk of acquiring Catheter – Associated Urinary Tract Infections (CAUTIs).
Available with latex foley catheter, all silicone foley catheter and hydrophilic foley catheters.
ComboPlus Foley
Catheter Tray

Infection control in a completely closed system

The tray offers a streamlined and efficient solution for foley catheterization procedures. It comes equipped with essential supplies to ensure safe and simple insertion while minimizing the risk of cross-infection.
Available for latex foley catheter, all silicone foley catheter and hydrophilic foley catheters.

The standard tray components include:

Ordering Information

Description

Pre-Connected Urine Meter

10mL preconnected to a top-mounted urine meter 2500mL, 1.1m tube, 2.0L bag, hanging straps, needle-free sample port (Luer)

ComboPlus Foley Catheter Tray

10mL preconnected to a top-mounted urine meter 2500mL, 1.1m tube, 2.0L bag, hanging straps, needle-free sample port (Luer) with standard components
Urine Meter for Medical Use
The urine meter is designed to collect and measure hourly diuresis in critically ill patients by connecting to urinary catheters. The metered chamber precisely measures the urine output, while the drainage bag collects urine, providing indicative volume information.
Reliable Measurement

High-precision measurement also with small volume

Fast and Precise Measuring

The well-defined, dark-colored scaling against the white background allows precise and quick measurement down to 1ml of volume.

Preservation of Fine Measurement

The measuring chamber design prevents loss of fine measurement when the system is placed on the bed, eg, during patient transport. Double-Lumen Tubing with Non-Return Valve

Splits the urine flow into 2 channels

Ensures reliable emptying into the chamber without backflow to the patient, also with small volumes. Minimizes the risk of urine stasis Available Length: 1.1m, 1.5m, 2m
Infection Control

Reliable Design Against Contamination

Top-Mounted Chamber Design
2 Non-Return Valves (NRV)
Helping to further minimize the risk of retrograde contamination
Closed-System with Efficient Venting
Ease of Use with Safety

One-hand hygienic and practical handling

Easy Empty Tab

With safe grip allows one-hand operation

Anti-Kink Spiral

Reduces the risk of blockage and urine stasis

Needle-Free Sampling Port

Effectively prevents needle – stick injuries

Safety T-Type with Large Outlet

Ensures one-hand operation with fast empty of the bag
Multiple Hanging Methods For Using on All Types of Beds

Hook

Cord

Straps

×